Cerritos College

Belden / Krone Data Cabling Approved Materials

For

Moves, Adds, and Changes in Existing Buildings Previously Cabled with Like-materials

Established March 4, 2004

 

The standard wiring configuration for Data outlets is T568B.

 

 

Materials required for data installations may include, but are not limited to:

 

Belden 1700A Blue DataTwist 350 Data Cable, blue or

Belden GigaFlex 1200 Data Cable, blue

ADC/Krone 6467 5 181-20 Category 5e Jack, white

ADC/Krone 6467 1 095-20 USOC Voice Jack, white

ADC/Krone 6644 1 174-01 Angled Faceplate, white

ADC/Krone 6644 1 224-01 4-Port All-Fit Box, white

ADC/Krone 6644 1 107-20 4-port 106 Adaptor, white

ADC/Krone 6644 1 165-20 4-port Walker 500-series Faceplate, white

ADC/Krone 6644 1 144-01 4-Port Modular Furniture Faceplate, white

ADC/Krone 6645 1 160-01 Blanks, white

ADC/Krone 6653 1 585-24 24-Port Patch Panel, black

ADC/Krone 6653 2 701-02 Horizontal Cable Organizer, black

ICC Horizontal Cable Management channel, black, ICCMSCMA52

Belden patch cords for patch panel end, blue (24 ea. per patch panel provided)

Belden 10ft. patch cords for station end, gray (24 ea. per patch panel provided)

CADDY CableCat or equivalent J-hooks for supporting of cables

Panduit or Wiremold surface cable raceway, white finish

CADDY, Arlington, or equal single-gang low voltage mounting bracket (after-set ring).

If raceway outlets are required for new lab:

 

Wiremold® 5400TBWH white finish two-compartment surface raceway

5400CWH full width covers

MXN2A08WH corner drop raceway base & cover (for vertical corner feed)

5410DFOWH divided entrance end

5411FOWH flat elbow

5415WH full capacity tee

5417FOWH internal elbow

5418WH external elbow

MXN2F21WH corner entrance fitting (for vertical corner feed)

5408LWH left transition fitting (for MXN2A08WH corner drop)

5408RWH right transition fitting (for MXN2A08WH corner drop)

5410WH end cap (for raceway ends)

 

5450WH device brackets (for mounting power outlets and data end plates)

 

CM-EPLA-WH end plates (to receive up to 3 CM2-U2NOR-WH modules)

CM2-U2NOR-WH Belden/CDT unloaded modules (to hold 2 Belden jacks)

CM2-BLWH blank insert (for unused openings of end plates)

 

5507DWH duplex faceplates (for electrical duplex, 1 per end plate)

5507BWH blank faceplates (for all unused openings of device brackets)

and all additional required fittings.

 

Use Belden AX101065 PS6+ data jacks for 5400-series raceway

 

 

All listed Wiremold components are white finish (WH suffix added to catalog number)

 

See additional installation standards here